Phone: (+39) 0813995453


Neck CT angiography in acute stroke: An open window for fast detection of COVID-19 lung involvement? Applicability in telemedicine

HumanInsight Neck CT angiography in acute stroke: An open window for fast detection of COVID-19 lung involvement? Applicability in telemedicine

PLoS One. 2023 Feb 24;18(2):e0281955. doi: 10.1371/journal.pone.0281955. eCollection 2023.

ABSTRACT

BACKGROUND: Chest CT has been proposed as a screening test to rule out SARS-CoV-2 lung infection in acute stroke. Our objectives are to analyze the predictive value of neck CT angiography (CTA) source images compared with conventional chest CT, the interobserver concordance and the reliability of the diagnosis using a mobile app.

METHODS: A retrospective observational study that included acute stroke patients admitted to a stroke center. Two raters blinded to the clinical data evaluated and classified the pulmonary findings in chest CT and neck CTA source images according to the COVID-19 Reporting and Data System (CO-RADS). CTA findings were evaluated using a conventional workstation and the JOIN mobile app. Scores of 3-5 were grouped as appearing typical or indeterminate for COVID-19 lung involvement and 0-2 as appearing atypical or negative for pneumonia. SARS-CoV-2 infection was confirmed by polymerase chain reaction (PCR).

RESULTS: A total of 242 patients were included (42 with PCR-confirmed COVID-19). In the cohort of 43 patients with both neck CTA and chest CT, the predictive value for COVID-19 was equivalent (sensitivity, 53.8%; specificity, 92.9%). The interobserver agreement in the classification into CO-RADS 3-5 or 1-2 in CTA was good (K = 0.694; standard error, 0.107). In the cohort of 242 patients with neck CTA, the intraobserver agreement between the workstation and the JOIN app was perfect (K = 1.000; standard error 0.000).

CONCLUSIONS: Neck CTA enables the accurate identification of COVID-19-associated lung abnormalities in acute stroke. CO-RADS evaluations through mobile applications have a predictive value similar to the usual platforms.

PMID:36827270 | DOI:10.1371/journal.pone.0281955

Powered by WPeMatico

P.IVA 08738511214
Privacy Policy
Cookie Policy

Sede Legale
Viale Campi Flegrei 55
80124 - Napoli

Sede Operativa
Via G.Porzio 4
Centro Direzionale G1
80143 - Napoli

ISO9001
AI 4394
© Copyright 2022 - Humaninsight Srls - All Rights Reserved
Privacy Policy | Cookie Policy
envelopephone-handsetmap-marker linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram